Antenna Feeder calibrated cable
CELLFLEX® 7/8″ low loss flexible cable
FEATURES
The reduced attenuation of CELLFLEX® coaxial cable results in extremly efficient signal transfer in your RF system, especially at high frequencies.
The solid outer conductor of CELLFLEX® coaxial cable creates a continuous RFI/EMI shield that minimizes system interference.
Special low VSWR versions of CELLFLEX® coaxial cables contribute to low system noise.
- Outstanding Intermodulation Performance
CELLFLEX® coaxial cable’s solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric materials, CELLFLEX® cable provides safe long term operating life at high transmit power levels.
- Wide Range of Application
Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects
| NFORMATION |
|---|
| Applications | | Main feed line, intended for outdoor usage |
|
| STRUCTURE |
|---|
| Size | | 7/8 | | Inner Conductor | mm (in) | 9.1 (0.358) | | Inner Conductor Material | | Copper Tube | | Dielectric | mm (in) | 21.5 (0.846) | | Dielectric Material | | Foam Polyethylene | | Outer Conductor | mm (in) | 25.2 (0.992) | | Outer Conductor Material | | Corrugated Copper | | Jacket | mm (in) | 27.8 (1.094) | | Jacket Material | | Black Polyethylene |
|
| TESTING AND ENVIRONMENTAL |
|---|
| Phase Stabilized | | Phase stabilized and phase matched cables and assemblies are available upon request. | | Compliance | | DIN EN ISO 9001:2015ISO 14001:2015 RoHS 2011/65/EU – China RoHS SJ/T 11364-2006 REACH (EC 1907/2006) UL1581 – UV Resistance Jacket IEC 60754-1/-2 | | Installation Temperature | °C(°F) | -40 to 60 (-40 to 140) | | Storage Temperature | °C (°F) | -70 to 85 (-94 to 185) | | Operation Temperature | °C(°F) | -50 to 85 (-58 to 185) |
|
| ELECTRICAL SPECIFICATIONS |
|---|
| Impedance | Ω | 50 +/- 1 | | Maximum Frequency | GHz | 5 | | Velocity | % | 88 | | Capacitance | pF/m (pF/ft) | 74 (22.5) | | Inductance | uH/m (uH/ft) | 0.185 (0.056) | | Peak Power Rating | kW | 85 | | RF Peak Voltage | Volts | 2920 | | Jacket Spark | Volt RMS | 8000 | | Inner Conductor dc Resistance | Ω/1000 m (Ω/1000 ft) | 2.04 (0.62) | | Outer Conductor dc Resistance | Ω/1000 m (Ω/1000 ft) | 2 (0.61) | | Passive Intermodulation PIM | min. dBc | -160 | | Return Loss (VSWR) Performance | | Standard 20dB (1.222) / Premium 23/24dB (1.152/1.135) on specified frequencies |
|
| MECHANICAL SPECIFICATIONS |
|---|
| Cable Weight, Nominal | kg/m (lb/ft) | 0.35 (0.23) | | Minimum Bending Radius, Single Bend | mm (in) | 120 (5) | | Minimum Bending Radius, Repeated Bends | mm (in) | 250 (10) | | Bending Moment | Nm (lb-ft) | 13 (10) | | Tensile Strength | N (lb) | 1440 (324) | | Recommended / Maximum Clamp Spacing | m (ft) | 0.8 / 1 (2.75 / 3.25) |
|
| ATTENUATION @ 20°C (68°F) AND POWER RATING @ 40°C (104°F) |
|---|
| Frequency, MHz | dB per 100m | dB per 100ft | Power, kW | | 1 | 0.11 | 0.03 | 85.00 | | 100 | 1.13 | 0.35 | 8.8 | | 200 | 1.62 | 0.49 | 6.14 | | 450 | 2.47 | 0.75 | 4.02 | | 700 | 3.12 | 0.95 | 3.19 | | 800 | 3.36 | 1.02 | 2.96 | | 900 | 3.57 | 1.09 | 2.78 | | 1800 | 5.21 | 1.59 | 1.91 | | 2000 | 5.53 | 1.68 | 1.80 | | 2200 | 5.83 | 1.78 | 1.70 | | 2400 | 6.12 | 1.86 | 1.62 | | 2700 | 6.54 | 1.99 | 1.52 | | 3000 | 6.94 | 2.11 | 1.43 | | 3500 | 7.57 | 2.31 | 1.31 | | 4000 | 8.17 | 2.49 | 1.22 | | 5000 | 9.30 | 2.83 | 1.07 |
|