Antenna Feeder calibrated cable
CELLFLEX® 7/8″ low loss flexible cable
FEATURES
The reduced attenuation of CELLFLEX® coaxial cable results in extremly efficient signal transfer in your RF system, especially at high frequencies.
The solid outer conductor of CELLFLEX® coaxial cable creates a continuous RFI/EMI shield that minimizes system interference.
Special low VSWR versions of CELLFLEX® coaxial cables contribute to low system noise.
- Outstanding Intermodulation Performance
CELLFLEX® coaxial cable’s solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric materials, CELLFLEX® cable provides safe long term operating life at high transmit power levels.
- Wide Range of Application
Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects
NFORMATION |
---|
Applications | | Main feed line, intended for outdoor usage |
|
STRUCTURE |
---|
Size | | 7/8 | Inner Conductor | mm (in) | 9.1 (0.358) | Inner Conductor Material | | Copper Tube | Dielectric | mm (in) | 21.5 (0.846) | Dielectric Material | | Foam Polyethylene | Outer Conductor | mm (in) | 25.2 (0.992) | Outer Conductor Material | | Corrugated Copper | Jacket | mm (in) | 27.8 (1.094) | Jacket Material | | Black Polyethylene |
|
TESTING AND ENVIRONMENTAL |
---|
Phase Stabilized | | Phase stabilized and phase matched cables and assemblies are available upon request. | Compliance | | DIN EN ISO 9001:2015ISO 14001:2015 RoHS 2011/65/EU – China RoHS SJ/T 11364-2006 REACH (EC 1907/2006) UL1581 – UV Resistance Jacket IEC 60754-1/-2 | Installation Temperature | °C(°F) | -40 to 60 (-40 to 140) | Storage Temperature | °C (°F) | -70 to 85 (-94 to 185) | Operation Temperature | °C(°F) | -50 to 85 (-58 to 185) |
|
ELECTRICAL SPECIFICATIONS |
---|
Impedance | Ω | 50 +/- 1 | Maximum Frequency | GHz | 5 | Velocity | % | 88 | Capacitance | pF/m (pF/ft) | 74 (22.5) | Inductance | uH/m (uH/ft) | 0.185 (0.056) | Peak Power Rating | kW | 85 | RF Peak Voltage | Volts | 2920 | Jacket Spark | Volt RMS | 8000 | Inner Conductor dc Resistance | Ω/1000 m (Ω/1000 ft) | 2.04 (0.62) | Outer Conductor dc Resistance | Ω/1000 m (Ω/1000 ft) | 2 (0.61) | Passive Intermodulation PIM | min. dBc | -160 | Return Loss (VSWR) Performance | | Standard 20dB (1.222) / Premium 23/24dB (1.152/1.135) on specified frequencies |
|
MECHANICAL SPECIFICATIONS |
---|
Cable Weight, Nominal | kg/m (lb/ft) | 0.35 (0.23) | Minimum Bending Radius, Single Bend | mm (in) | 120 (5) | Minimum Bending Radius, Repeated Bends | mm (in) | 250 (10) | Bending Moment | Nm (lb-ft) | 13 (10) | Tensile Strength | N (lb) | 1440 (324) | Recommended / Maximum Clamp Spacing | m (ft) | 0.8 / 1 (2.75 / 3.25) |
|
ATTENUATION @ 20°C (68°F) AND POWER RATING @ 40°C (104°F) |
---|
Frequency, MHz | dB per 100m | dB per 100ft | Power, kW | 1 | 0.11 | 0.03 | 85.00 | 100 | 1.13 | 0.35 | 8.8 | 200 | 1.62 | 0.49 | 6.14 | 450 | 2.47 | 0.75 | 4.02 | 700 | 3.12 | 0.95 | 3.19 | 800 | 3.36 | 1.02 | 2.96 | 900 | 3.57 | 1.09 | 2.78 | 1800 | 5.21 | 1.59 | 1.91 | 2000 | 5.53 | 1.68 | 1.80 | 2200 | 5.83 | 1.78 | 1.70 | 2400 | 6.12 | 1.86 | 1.62 | 2700 | 6.54 | 1.99 | 1.52 | 3000 | 6.94 | 2.11 | 1.43 | 3500 | 7.57 | 2.31 | 1.31 | 4000 | 8.17 | 2.49 | 1.22 | 5000 | 9.30 | 2.83 | 1.07 |
|